FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Air USA

Address
Attention: Marco Parzych
Street Address: 1659 Hwy 104
P.O. Box:
City: Quincy
State: IL
Zip Code: 62305
Country:
E-Mail Address: marco.parzych@air-usa.com

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Cortez
First Name: Anne
Title: Counsel
Phone Number: 520-360-0925

Explanation
Please explain in the area below why an STA is necessary:
operations are limited to 60 days, so an STA is appropriate

Purpose of Operation
Please explain the purpose of operation:  testing radar system after aircraft repairs to verify performance

Information
Callsign: WK2XBG
Class of Station: MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 05/01/2022
Operation End Date: 06/30/2022

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
xxxxx xxxx 12 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Marco Parzych
Title of Applicant (if any): Training Officer, Dep. Program Manager
Date: 2022-03-24 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Quincy Illinois North  39  56  10 West  91  11  58 Quincy, IL 40.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 245MQ1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 4M05Q1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 4M40Q1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 60M7Q1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 8M20Q1N BPSK

City State Latitude Longitude Mobile Radius of Operation
Missouri North  38  39  55 West  90  39  6 40 km radius around Spirit of St. Louis Airport 40.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   Yes
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 245MQ1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 4M05Q1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 4M40Q1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 60M7Q1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 8M20Q1N BPSK

City State Latitude Longitude Mobile Radius of Operation
Texas North  33  42  50 West  96  40  12 around North Texas Regional Airport 40.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   Yes
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 245MQ1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 4M05Q1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 4M40Q1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 60M7Q1N BPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9400.00000000-10000.00000000 MHz MO 384.000000 W 186.000000 kW P 8M20Q1N BPSK