By the instant request ("Application"), BAE Systems Information and Electronic Systems Integration Inc. ("BAE Systems") requests that the Commission grant Special Temporary (STA) to operate the facilities specified in the Application.

Purpose of Operation
Please explain the purpose of operation:  To involve proof of concept for next generation airborne COMINT (Communication Intelligence) for UAV’s.

Information
Callsign: WF9XEN
Class of Station: MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 10/23/2011
Operation End Date: 04/23/2012

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Please See Exhibit 1 1 1 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Don Haes
Title of Applicant (if any): CHP
Date: 2011-09-23 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Hudson New Hampshire North  42  48  22 West  71  25  33 Temporary Fixed Locations (Ground), Hudson, NH 0.45
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   18.30
(b) Elevation of ground at antenna site above mean sea level in meters:   61.00
(c) Distance to nearest aircraft landing area in kilometers:   7.83
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: None
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10.25000000- GHz MO 1.000000 W 50.000000 W P 150MF3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10.25000000- GHz MO 1.000000 W 50.000000 W P 500MF3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10.25000000- GHz MO 1.000000 W 50.000000 W P 75M0F3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2365.00000000-2445.00000000 MHz MO 1.000000 W 3.160000 W P 2M40G1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2365.00000000-2445.00000000 MHz MO 1.000000 W 3.160000 W P 4M79G1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2365.00000000-2445.00000000 MHz MO 1.000000 W 3.160000 W P 9M58G1D

City State Latitude Longitude Mobile Radius of Operation
Hudson New Hampshire North  42  48  22 West  71  25  33 Mobile Operations (Ground), Hudson, NH 0.45
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1760.00000000-1840.00000000 MHz MO 1.000000 W 3.160000 W P 2M40G1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1760.00000000-1840.00000000 MHz MO 1.000000 W 3.160000 W P 4M79G1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1760.00000000-1840.00000000 MHz MO 1.000000 W 3.160000 W P 9M58G1D