FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Battelle

Address
Attention: Richard W. Ridgway
Street Address: 505 King Ave
P.O. Box:
City: Columbus
State: OH
Zip Code: 43201
Country:
E-Mail Address: ridgway@battelle.org

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Ridgway
First Name: Richard
Title: Senior Research Leader
Phone Number: 614-424-5140

Explanation
Please explain in the area below why an STA is necessary:
Battelle would like perform outdoor tests on an experimental point-to-point communications link operating at millimeter-wave frequencies.

Purpose of Operation
Please explain the purpose of operation:  The purpose of this communications link is to provide extremely high data transmission between two points.

Information
Callsign: WE9XGU
Class of Station: FX
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 02/01/2011
Operation End Date: 08/01/2011

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Battelle NA 1 Yes

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Richard W. Ridgway
Title of Applicant (if any): Senior Research Leader
Date: 2011-01-11 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Columbus Ohio North  39  59  22 West  83  1  13 0.10
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   0.60
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 95.00000000-105.00000000 GHz FX 10.000000 mW 2.000000 kW M 10G0A1D 10 Gb/s

City State Latitude Longitude Mobile Radius of Operation
West Jefferson Ohio North  39  57  18 West  83  15  14 1.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   0.60
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 95.00000000-105.00000000 GHz FX 10.000000 mW 2.000000 kW M 10G0A1D 10 Gb/s

City State Latitude Longitude Mobile Radius of Operation
Galloway Ohio North  39  56  33 West  83  11  41 2.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   Yes
(a) Width of beam in degrees at the half-power point:   0.60
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 95.00000000-105.00000000 GHz FX 10.000000 mW 2.000000 kW M 10G0A1D 10 Gb/s